Skip to main content

Dr Prashant Kadam

LIVER TRANSPLANT +
CANCER SURGERY +
LIVER TRANSPLANT
GALL BLADDER SURGERY +
BILIARY SURGERY +
CANCER SURGERY
LIVER TRANSPLANT +
PANCREATIC SURGERY
CANCER SURGERY +
LIVER TRANSPLANT
LIVER SURGERY +
CANCER SURGERY

How Does Machine Perfusion Preserve a Donor Liver Before Transplantation?

Medically reviewed by Dr. Prashant Kadam | Last reviewed: November 2026

Machine perfusion in liver transplantation preserves a donor liver by circulating a specially prepared fluid through its blood vessels outside the body. Depending on the method, this fluid supplies oxygen and other substances that support the liver’s cells. Donor liver preservation matters because the organ no longer receives its normal blood supply after removal. Traditionally, liver preservation before transplant has relied on chilling the organ in a preservation solution.

Machine perfusion offers another way to control conditions during this interval. It is used mainly for deceased-donor organs, with the method chosen according to the liver, the equipment and the transplant team’s assessment. It can support preservation and assessment, but cannot guarantee a successful transplant or remove the need for careful recipient assessment.

Key takeaways:

  • Machine perfusion keeps fluid, and usually oxygen, flowing through a donor liver between retrieval and transplant, instead of leaving it still on ice.
  • Cold perfusion mainly protects the liver, especially the bile ducts. Warm perfusion also lets the team watch the liver work before deciding to use it.
  • Trials show less injury and fewer discarded organs, but no proven improvement in patient survival so far, and the technique adds cost and complexity.

How Does a Liver Perfusion Machine Work?

Machine perfusion of the liver uses a liver perfusion machine to circulate fluid through tubes connected to the organ’s main blood vessels. Pumps, an oxygenator and temperature controls maintain the planned conditions. The fluid, called perfusate, passes through the liver and returns through the circuit.

During oxygenated perfusion, oxygen reaches the liver’s cells through this circulation. Warm systems may also supply nutrients and an oxygen carrier, such as red blood cells. Cold systems use different fluids and settings.

During machine perfusion before liver transplant, the donor liver remains outside the body. This is preservation, not surgery on the recipient. Trained staff monitor pressures, flow, temperature and other measurements appropriate to the method. They assess the organ’s response and adjust the circuit according to the centre’s protocol.

What Are the Main Types of Machine Perfusion?

The approaches differ in temperature, in where the perfusion takes place and in what they are meant to achieve. Two are carried out on the liver after it has been removed; a third is carried out inside the donor.

Normothermic Machine Perfusion

Normothermic machine perfusion (NMP) keeps the liver close to body temperature. An oxygen-carrying fluid supports its activity, so the liver behaves much as it would in the body. During normothermic liver perfusion, staff can monitor how the liver handles substances in the fluid and whether it produces bile, which helps them judge an organ they are unsure about.

Hypothermic Oxygenated Perfusion

Hypothermic oxygenated perfusion (HOPE) keeps the liver cold while circulating an oxygen-rich preservation fluid. Lower temperatures reduce the cells’ energy requirements, while oxygen delivery helps recharge the cells and limits the injury that occurs when blood flow is restored in the recipient. Hypothermic liver perfusion is often applied for the last hour or two before implantation, after the liver has travelled on ice. It does not provide the same functional assessment as warm perfusion.

Normothermic Regional Perfusion

Normothermic regional perfusion (NRP) is used in donation after circulatory death, where the heart has stopped before retrieval. Blood flow is restored to the abdominal organs inside the donor’s body for a few hours before the liver is cooled and removed. It needs a specialised team and operates within each country’s legal and ethical framework for this type of donation.

 

Hypothermic (HOPE)

Normothermic (NMP)

Regional (NRP)

Temperature

Cold

Body temperature

Body temperature

Where

Outside the body

Outside the body

Inside the donor

Typical duration

Often 1–2 hours before implantation

Usually 3–16 hours

About 2–4 hours

Main purpose

Protect cells and bile ducts

Preserve and test function

Restore blood flow after circulatory death

Function testing

Limited

Yes

Yes

 

Neither approach is automatically preferable. Selection depends on the donor liver, its preservation history and the team’s plan, and some protocols combine a cold stage with a warm stage. The protocols are not interchangeable.

Machine Perfusion vs Cold Storage for Liver Transplantation

Cold storage keeps the liver chilled in a special preservation solution without continuous circulation. Cooling slows cellular activity and reduces oxygen requirements. It is simple, portable and inexpensive, and it remains the established approach to organ preservation for transplantation worldwide.

Machine perfusion circulates fluid through the liver. Depending on the method, it supplies oxygen and allows additional monitoring. Some protocols use cold storage for transport, followed by perfusion at the receiving hospital.

Comparing machine perfusion vs cold storage therefore involves more than choosing between ice and a machine. Three studies show what has and has not been demonstrated:

  • Warm perfusion (Nature, 2018): In a randomised trial of 220 liver transplants, normothermic preservation was associated with about 50% less graft injury and about 50% fewer discarded organs, even though livers were preserved for longer. Bile duct complications, graft survival and patient survival did not differ significantly.
  • Cold oxygenated perfusion (New England Journal of Medicine, 2021): In 160 patients receiving livers donated after circulatory death, a period of hypothermic oxygenated perfusion reduced a serious form of bile duct narrowing from 18% to 6%.
  • Testing declined livers (Nature Communications, 2020): In the VITTAL trial, 31 livers that every UK centre had declined were tested on a warm perfusion machine. Twenty-two (71%) met the viability criteria and were transplanted, and all 22 recipients and grafts survived to 90 days. Four recipients later developed bile duct narrowing that required another transplant.

Results therefore differ by method and donor circumstances. These liver preservation techniques also require different equipment, staffing and logistics. New liver transplant technology does not make cold storage unnecessary in every case.

What Are the Benefits of Machine Perfusion for Liver Transplant?

Potential benefits of machine perfusion for liver transplant include supporting preservation and giving doctors more information about donor liver quality. Assessment can be difficult when an organ has experienced reduced blood supply or comes from a donor with additional risk factors.

Can doctors test a donor liver before transplantation? With some perfusion methods, they can observe useful indicators:

  • Lactate clearance: Lactate is a substance the liver normally helps clear from the blood. A falling level suggests the liver cells are working.
  • Bile production and quality: Whether the liver makes bile, and the acidity, bicarbonate and sugar content of that bile, which reflect the health of the bile ducts.
  • Acid–base balance: Whether the liver keeps the fluid’s pH stable.
  • Flow and resistance: How easily fluid passes through the liver’s blood vessels.
  • Appearance: How evenly the liver perfuses and how it looks and feels.

These findings contribute to assessing donor liver viability: whether the organ appears capable of functioning after transplant. No single reading proves suitability, and there is no agreed combined score yet. The team also reviews donor history, organ appearance, investigations and the recipient’s needs. Perfusion may allow some previously rejected organs to be considered, but uncertainty remains. Bile production alone is not conclusive.

What Are the Limitations of Machine Perfusion?

Machine perfusion is not a guarantee, and it has practical drawbacks:

  • Cost and staffing: Devices, disposables and trained staff add expense compared with cold storage.
  • Logistics: Machines must be transported or set up at the receiving hospital, which affects timing in the operating theatre.
  • Evidence gaps: Pooled trial data have not shown an improvement in patient survival, and most guidance still rests on observational studies.
  • No standard test: Centres use different viability criteria, so a liver accepted by one team might be declined by another.

How Long Can a Donor Liver Be Preserved Before Transplant?

There is no single safe preservation time for every liver. It depends on the organ’s condition, previous periods without normal blood flow and the preservation method. As a general guide:

  • Cold storage: Results tend to decline once a liver has been stored for more than about 8 to 12 hours, and sooner for higher-risk organs.
  • Hypothermic oxygenated perfusion: Commonly applied for one to two hours at the end of cold storage, though it can run for longer.
  • Normothermic machine perfusion: Usually 3 to 16 hours. In the VITTAL trial, the median total preservation time was 18 hours.
  • Research settings: In 2022, a team in Zurich reported transplanting a liver after three days on a perfusion machine. This was a single research case, not routine practice.

Machine perfusion for liver transplant can therefore extend the window and turn some night-time emergencies into planned daytime operations, but this does not establish a safe limit for every organ.

Ask your team, “How is a donor liver preserved before transplantation?” Their explanation should cover the method and timetable. Research into longer preservation continues, while teams coordinate retrieval, transport and surgery carefully. A machine does not remove time-related risks.

Can Machine Perfusion Make More Donor Livers Suitable for Transplant?

It may. The clearest evidence is that warm perfusion lets teams test organs they would otherwise decline: in the 2018 trial fewer livers were discarded, and in VITTAL about seven in ten previously declined livers went on to be transplanted. Assessment is not confirmation that every damaged liver can be used, and some organs fail the test.

In India, the effect on overall numbers is limited by how transplants are done. In 2022, about four in five of the country’s 3,920 liver transplants used a living donor, and machine perfusion is designed mainly for deceased-donor livers. Its value lies in making the most of each deceased-donor organ, particularly those from older donors, donors with fatty livers or livers that have travelled a long distance. As deceased donation grows, that role is likely to grow with it.

For people considering liver transplant surgery in India, availability depends on equipment, experience and centre protocols. Dr. Prashant Kadam’s services page lists machine perfusion among his areas of practice; ask what is available for the specific case.

Searching for the “best doctor for liver transplant in India” should involve reviewing team experience, safety, facilities and follow-up. Anyone considering medical tourism in India for liver transplant should also clarify ongoing care after returning home. Formal transplant eligibility still requires individual assessment by the team.

For a wider look at how preservation techniques are changing transplant care, read our article on advancements in liver preservation and machine perfusion. If you are weighing your own options, see who needs a liver transplant and when.

About Dr. Prashant Kadam

Dr. Prashant Kadam is a Senior Consultant in Liver Transplant and HPB Surgery at Sir H. N. Reliance Foundation Hospital, Girgaon, Mumbai. He trained in HPB surgery and liver transplantation at Queen Elizabeth Hospital, Birmingham, and his areas of expertise include machine perfusion techniques for donor liver preservation.

To discuss your case, you can book an appointment through the contact page or call +91 98339 56489.

FAQs About Machine Perfusion in Liver Transplantation

What is machine perfusion in liver transplantation?

It is a way of preserving a donor liver outside the body by pumping a prepared fluid, usually carrying oxygen, through its blood vessels. It is used between retrieval and transplant, either cold to protect the organ or warm to keep it working and allow testing.

How does a liver perfusion machine work?

Tubes connect the liver’s main blood vessels to a circuit with a pump, an oxygenator and a temperature control unit. Fluid flows through the liver and back again while staff monitor pressure, flow and temperature. The precise settings depend on the system and the centre’s protocol.

Is machine perfusion better than cold storage?

In selected situations, yes. Trials show less liver injury, fewer discarded organs and, for some donor types, fewer bile duct complications. Patient survival has not been shown to improve, and cold storage remains appropriate for many good-quality livers with short transport times.

How long can a liver stay on a perfusion machine?

Warm perfusion usually lasts between 3 and 16 hours, and cold oxygenated perfusion often one to two hours before implantation. Longer periods have been reported in research. The safe duration depends on the individual liver and the method used.

Can machine perfusion make more donor livers suitable for transplant?

It may help teams assess and use some organs that would otherwise be declined. In one UK trial, about seven in ten previously declined livers passed testing and were transplanted. Not every liver passes, and the decision remains a clinical judgement.

Is machine perfusion used in living donor liver transplants?

Rarely. In living donation the portion of liver usually moves from donor to recipient within a short time, so prolonged preservation is not needed. Machine perfusion is used mainly for livers from deceased donors.

Can machine perfusion guarantee a successful liver transplant?

No. Liver quality, the recipient’s health, the surgery and follow-up care all affect outcomes. Perfusion gives the team more information and may reduce certain complications, but it cannot remove the risks of transplantation.

References

  1. Nasralla D, Coussios CC, Mergental H, et al. A randomized trial of normothermic preservation in liver transplantation.  https://pubmed.ncbi.nlm.nih.gov/29670285/
  2. van Rijn R, Schurink IJ, de Vries Y, et al. Hypothermic machine perfusion in liver transplantation: a randomized trial. N Engl J Med. 
  3. Mergental H, Laing RW, Kirkham AJ, et al. Transplantation of discarded livers following viability testing with normothermic machine perfusion. Nat Commun. https://www.nature.com/articles/s41467-020-16251-3
  4. Clavien PA, Dutkowski P, Mueller M, et al. Transplantation of a human liver following 3 days of ex situ normothermic preservation. Nat Biotechnol. https://pubmed.ncbi.nlm.nih.gov/35641829/
  5. American Association for the Study of Liver Diseases, Liver Fellow Network. Why machine perfusion has the potential to change the liver transplant landscape, and why hasn’t it yet? https://aasld.org/liver-fellow-network/core-series/why-series/why-machine-perfusion-has-potential-change-liver
  6. Tiwari P, Nundy S. The status of liver transplantation in India. Natl Med J India.

This article is for general information only and does not replace medical advice. How a donor liver is preserved, and whether a transplant is suitable, is decided by a qualified transplant team for each individual case.

Medically Reviewed by

Dr. Prashant Kadam

MBBS
MS (Gen Surgery)
MRCS (Edinburgh)
M.Ch. (Surgical Oncology)
FRCS (Edinburgh)
FEBS (Transplant Surgery)

Follow Me

Schedule Appointment

Fill out the form below, and we will be in touch shortly.